| Test | Pre-Conditioning | Ignition Seconds | Smoke Density | Criteria | |||
|---|---|---|---|---|---|---|---|
| After Flame | Flame Spread | Flaming Driplets | |||||
![]() California Title 19 Tests: After Flame State Certified |
Room temperature / Average humidity for at least 10 days |
12 sec. in a chamber |
N/A |
10 sec. Max |
None is allowed |
Driplets must self-extinguish when hitting chamber floor |
Flame Resistant Product |
![]() US Gov SIN 4722-06 Tests: After Flame Government Test |
Soaking in water for 2-3 hours |
12 sec. in a chamber |
N/A |
15-18 sec. Max |
N/A |
None allowed |
|
![]() ASTME 84-95 Class A (similar to UL723) Tests: Smoke Density & Flame Spread Strictly Measurements, not pass/fail |
Oven dried at 140-150 degrees for 90 minutes |
12 sec. in a chamber |
N/A |
2 sec. Max |
3.5"-6.5" max char length |
Driplets must extinguish when hitting chamber floor |
|
|
Oven dried at 140-150 degrees for 90 minutes |
12 sec. in a chamber |
N/A |
2 sec. Max |
3.5"-6.5" max char length |
Driplets must extinguish when hitting chamber floor |
|
![]() NFPA 701 1996 & 1999 Small Scale Tests: After Flame & Weight Loss |
Oven dried at 105 degrees for 30 minutes |
45 sec. in a chamber |
N/A |
2 sec. Max |
N/A flame spread, but no more than 40% weight loss |
Driplets must extinguish no more than 2 sec. after hitting chamber floor. |
|
![]() NFPA 705 1997 Field Flame Test Tests: After Flame & Flame Spread |
None |
Field tested in draft area with wooden match (or equivalent) for 12 sec. |
N/A |
2 sec. Max |
4" max char length |
Driplets must self-extinguish when hitting chamber floor |
|